Preliminary Design



Save, fill-In The Blanks, Print, Done!

Click on image to zoom / Click button below to see more images
Adobe Acrobat (.pdf)

  • This Document Has Been Certified by a Professional
  • 100% customizable
  • This is a digital download (1646.48 kB)
  • Language: English
  • We recommend downloading this file onto your computer.


  
ABT template rating: 8

Malware- and virusfree. Scanned by: Norton safe website

Are you looking for a professional Preliminary Design? If you've been feeling stuck or lack motivation, download this template now!

Do you have an idea of what you want to draft, but you cannot find the exact words yet to write it down or lack the inspiration how to make it? If you've been feeling stuck, this Preliminary Design template can help you find inspiration and motivation. This Preliminary Design covers the most important topics that you are looking for and will help you to structure and communicate in a professional manner with those involved. 

Preliminary Design Report March 13, 2015 Preliminary (30 ) Design Report RS-G341 Conveyance Improvements Phase 1: Bolles East (L-16) Canal Conveyance Improvement Project Prepared for: South Florida Water Management District South Florida Water Management District RS‐G341 Conveyance Improvements Phase 1: Bolles East (L16) Canal Conveyance Improvement Project Design Report (DR) for Preliminary (30 ) Design March 13, 2015 Prepared by J‐Tech for the South Florida Water Management District Work Order No.. Table 4.3 ‐ Maximum Canal Velocities (ft/s) MODEL RIVER MILE REMOVAL VOLUMES FEATURE CONVEYANCE ¾” 1” 1¼ 1½ 6281 Star Farms Br, W 2.12 2.23 2.28 2.38 0.64 6311 Star Farms Br, E 1.8 1.89 1.94 2.02 0.52 10046 Kennedy Farms Br, W 2.13 2.23 2.29 2.38 0.91 10090 Kennedy Farms Br, E 2.13 2.23 2.29 2.38 0.93 12771 Boca Chica Rd Br, W 2.02 2.16 2.26 2.39 1.21 12829 Boca Chica Rd Br, E 2.02 2.19 1.19 1.22 1.21 23552 Duda Road culverts, W 0.28 0.21 0.21 0.22 0.39 23622 Duda Road culverts, E 0.19 0.19 0.19 0.20 0.28 37788 Jett Farms Br, W 2.32 2.43 2.50 2.57 0.66 37844 Jett Farms Br, E 2.32 2.44 2.52 2.59 0.66 47107 Browns Farm culverts, W 1.22 1.36 1.40 1.46 0.24 47208 Browns Farm culverts, E 0.05 0.06 0.06 0.06 0.24 Page 18 RS‐G341 Conveyance Improvements Phase 1: Bolles East (L16) Canal Conveyance Improvement Project Design Report for Preliminary Design 4.3 Evaluated Alternatives Model Results After preliminary analyses and discussion with the District, the two agreed‐upon improvement scenarios were:  Alternative 1: 40‐ft wide canal bottom at el.. exis ting (updated 20150101) Plan: bw 40-2nonegbrw brdg20150305150in Geom: bw40e-2wbrdg20150305x 2007 .05 3/8/2015 Flow: .04 .05 20 Legend WS Max WS Ground Lev ee Inef f 15 Bank Sta Elevation (ft) 10 5 0 -5 0 50 100 150 200 250 300 Station (f t) Figure 4.18 ‐ Alt 1 ‐ Canal Improvements exis ting (updated 20150101) Plan: bw 40-2nonegbrw brdgimp20150305150in Geom: bw40e-2wbrdgimp20150305x 2007 .05 3/8/2015 Flow: .04 .0

Feel free to download this intuitive template that is available in several kinds of formats, or try any other of our basic or advanced templates, forms or documents. Don't reinvent the wheel every time you start something new... 

Download this Preliminary Design template and save yourself time and efforts! You will see completing your task has never been simpler!
 




DISCLAIMER
Nothing on this site shall be considered legal advice and no attorney-client relationship is established.


Leave a Reply. If you have any questions or remarks, feel free to post them below.


default user img

To think creatively, we must be able to look afresh at what we normally take for granted. | George Kneller